The certificates every let needs (gas, electrical, EPC, alarms)
A private let in England needs a gas safety record every year, an electrical report every five years, an EPC rated E or better, and working smoke and carbon monoxide alarms. What each one is, how often, and what happens if you let without it.
In short: A let home in England needs a gas safety check every 12 months, an electrical report (EICR) at least every five years, an EPC rated E or better, a smoke alarm on every storey and carbon monoxide alarms where the law requires. The tenant must be given a copy of each certificate.
Safety certificates and the home
England. Checked against the law on 29 September 2026. Information, not legal advice.
Gas safety record (every 12 months)
If the property has any gas appliance or flue, a Gas Safe registered engineer must check it every year and give you a record (the CP12). Give the tenant a copy within 28 days, and to new tenants before they move in. Letting without one is a criminal offence and blocks possession.
Electrical installation condition report, EICR (every 5 years)
Required for every private tenancy in England since 2021. A qualified electrician tests the fixed wiring and grades it. C1 and C2 faults must be fixed within 28 days. Give a copy to the tenant and to the council if asked.
Energy performance certificate, EPC (every 10 years)
The property needs a valid EPC, and it must be rated E or better to be let (the Government has consulted on raising this to C for new tenancies later this decade; check the current position). Show the rating in any advert.
Smoke and carbon monoxide alarms (always)
At least one smoke alarm on every storey with living accommodation, and a carbon monoxide alarm in any room with a fixed combustion appliance (a gas boiler counts; a gas cooker does not). Test them on the first day of the tenancy and record it. Repair or replace when a tenant reports a fault.
Others that may apply
- Licence: a mandatory HMO licence for five or more people from two or more households, or a selective or additional licence if your council runs a scheme in that area.
- Legionella risk assessment (you can do it yourself for a simple property).
- Fire safety in HMOs and blocks of flats.
How LevelMoves helps
Upload the certificate, in any form: a PDF, a photo of the paper. The PA reads it, files it against the property, records the expiry and shows it on your dashboard before it lapses. Booking an engineer is an ask-first action: it finds a slot and you tap yes.
Where this comes from
Questions landlords ask
Do I need an EICR for a single let?
Yes. Since 1 April 2021 every private tenancy in England needs an electrical installation condition report, renewed at least every five years.
What EPC rating do I need to let a property?
E or better, unless a valid exemption is registered. Watch for the planned rise to C, which the Government has consulted on for new tenancies.
Where must the carbon monoxide alarm go?
In every room used as living accommodation that has a fixed combustion appliance, such as a gas boiler or a wood burner. A gas cooker alone does not trigger the requirement.
Read next
Guide
Landlord compliance checklist (England)
Every legal check for a private let in England in one list: gas, EICR, EPC, alarms, deposit, right to rent, the information sheet and the landlord database.
Guide
What is the minimum EPC rating to let a home in England?
A home you let in England needs an EPC rated E or better, unless an exemption is on the PRS Exemptions Register. The planned rise to C from 1 October 2030 is government policy but still needs new law.
Guide
Do I need a licence to let my property? HMO, additional and selective licensing
Five or more people from two or more households need a mandatory HMO licence. Your council may also license smaller HMOs, or every let in an area. How to check, and what happens without one.
Guide
How often does a landlord need an EICR?
Every private let in England needs the electrics inspected and tested at least every five years. Copies to the tenant within 28 days, urgent repairs within 28 days, and a council fine of up to £40,000.
Templates, terms and news on this
Glossary
Category 1 hazard
The most serious level of hazard under the HHSRS. When a council finds one in a home, it must take enforcement action.
Glossary
EICR codes: C1, C2, C3 and FI
The codes an electrician uses on an EICR: C1 danger present, C2 potentially dangerous, FI further investigation needed, C3 improvement recommended.
Glossary
Electrical installation condition report (EICR)
A report by a qualified electrician on the safety of a home's fixed wiring. Every private let in England needs one at least every five years.
Glossary
Energy performance certificate (EPC)
A certificate rating a home's energy efficiency from A (best) to G, valid for ten years. Needed before a home is let or sold, and shown in adverts.
Read enough? Upload a document to start.
The PA keeps every date in this guide for you and asks before anything that costs money.